TY - JOUR
T1 - Medical equipment deployment in pediatric emergency prehospital medical units in Japan
AU - Kaku, Noriyuki
AU - Nitta, Masahiko
AU - Muguruma, Takashi
AU - Hirata, Yuichiro
AU - Tsukahara, Kohei
AU - Knaup, Emily
AU - Nosaka, Nobuyuki
AU - Enomoto, Yuki
N1 - Publisher Copyright:
© 2018 Japan Pediatric Society
PY - 2018/1
Y1 - 2018/1
N2 - The deployment status of pediatric emergency equipment in ambulances in Japan is unknown. To investigate the status of and issues associated with prehospital emergency medical care for pediatric patients, we conducted a descriptive epidemiological study. We carried out a Web-based survey of 767 fire defense headquarters in Japan, of which 671 responded (valid response rate, 88%). Most of the fire defense headquarters equipped all of their ambulances with oxygen masks (82%), bag-valve masks (for neonates, 83%; for children, 84%), straight laryngoscope blades (for neonates, 47%; for children 68%), blood pressure cuffs for children (91%), oximeter probes (78%), and stiff neck collars (91%); but despite the need for other equipment such as nasopharyngeal and oropharyngeal airways, and Magill forceps, they were insufficiently deployed. In Japan, prehospital emergency medical equipment deployment does not meet the needs of pediatric patients. Minimum equipment standards need to be established for pediatric prehospital care.
AB - The deployment status of pediatric emergency equipment in ambulances in Japan is unknown. To investigate the status of and issues associated with prehospital emergency medical care for pediatric patients, we conducted a descriptive epidemiological study. We carried out a Web-based survey of 767 fire defense headquarters in Japan, of which 671 responded (valid response rate, 88%). Most of the fire defense headquarters equipped all of their ambulances with oxygen masks (82%), bag-valve masks (for neonates, 83%; for children, 84%), straight laryngoscope blades (for neonates, 47%; for children 68%), blood pressure cuffs for children (91%), oximeter probes (78%), and stiff neck collars (91%); but despite the need for other equipment such as nasopharyngeal and oropharyngeal airways, and Magill forceps, they were insufficiently deployed. In Japan, prehospital emergency medical equipment deployment does not meet the needs of pediatric patients. Minimum equipment standards need to be established for pediatric prehospital care.
UR - http://www.scopus.com/inward/record.url?scp=85040805989&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85040805989&partnerID=8YFLogxK
U2 - 10.1111/ped.13432
DO - 10.1111/ped.13432
M3 - Article
C2 - 29356286
AN - SCOPUS:85040805989
SN - 1328-8067
VL - 60
SP - 93
EP - 95
JO - Pediatrics International
JF - Pediatrics International
IS - 1
ER -