Loading tests of beam-column subassemblages having exterior diaphragms composed of two steel plates

Shintaro Matsuo, Kazuhiro Saburi, Tsuyoshi Tanaka, Kazuo Inoue

Research output: Contribution to journalArticlepeer-review

1 Citation (Scopus)

Abstract

This paper proposes design procedures that yielding of beams occurs before RHS-column to beam connections stiffened by exterior diaphragms yield. Cyclic loading tests of beam-column subassemblages for interior columns were conducted in order to verify the validity of the proposed design method, and elasto-plastic behaviors of beam-column subassemblages for exterior column or concrete filled tube column were investigated. The test results reveal that the design method is valid. Stiffness of beams with exterior diaphragms can be properly predicted by assuming that beams are connected rigidly to columns. Deformation capacities of specimens whose beams are connected to exterior diaphragms with high-strength bolts are substantially larger than that of the specimen that beam flanges and exterior diaphragms are welded.

Original languageEnglish
Pages (from-to)425-433
Number of pages9
JournalJournal of Structural and Construction Engineering
Volume75
Issue number648
DOIs
Publication statusPublished - Feb 2010
Externally publishedYes

All Science Journal Classification (ASJC) codes

  • Architecture
  • Building and Construction

Fingerprint

Dive into the research topics of 'Loading tests of beam-column subassemblages having exterior diaphragms composed of two steel plates'. Together they form a unique fingerprint.

Cite this