TY - JOUR
T1 - Late-onset right ventricular failure in patients with preoperative small left ventricle after implantation of continuous flow left ventricular assist device
AU - Imamura, Teruhiko
AU - Kinugawa, Koichiro
AU - Kato, Naoko
AU - Muraoka, Hironori
AU - Fujino, Takeo
AU - Inaba, Toshiro
AU - Maki, Hisataka
AU - Kinoshita, Osamu
AU - Hatano, Masaru
AU - Kyo, Shunei
AU - Ono, Minoru
N1 - Copyright:
Copyright 2014 Elsevier B.V., All rights reserved.
PY - 2014
Y1 - 2014
N2 - Background: The continuous flow (CF) left ventricular assist device (LVAD) has replaced the pulsatile flow (PF) LVAD because of its advantages of better patient survival and higher quality of life. However, "late-onset right ventricular failure (RVF)" after CF LVAD implantation has emerged as an increasing concern, but little is known about the mechanism. Methods and Results: We retrospectively analyzed the 3-month hemodynamic and echocardiographic data from 38 consecutive patients who had received CF LVADs, and from 22 patients who had received PF LVADs. Late-onset RVF was defined as persistent right ventricular stroke work index (RVSWI) <4.0 g/m2 at any rotation speed and after saline infusion test at 5 weeks after implantation of CF LVAD. Patients with late-onset RVF had significantly impaired exercise tolerance indicated by shorter 6-min walking distance and lower peak V ̇O2, and worsened tricuspid regurgitation, together with enlargement of the RV under CF LVAD treatment (all P<0.05). Univariable analyses demonstrated that preoperative smaller LV diastolic diameter (LVDd) was the risk factor for late-onset RVF with a cutoff value of 64 mm calculated by ROC analysis (area under curve, 0.925). In contrast, there was no correlation between preoperative LVDd and postoperative RVSWI in the PF LVAD group, though their preoperative background was worse than that of the CF group. Conclusions: In the setting of preoperative small LVDd, CF LVAD may cause late-onset RVF by leftward shift of the interventricular septum.
AB - Background: The continuous flow (CF) left ventricular assist device (LVAD) has replaced the pulsatile flow (PF) LVAD because of its advantages of better patient survival and higher quality of life. However, "late-onset right ventricular failure (RVF)" after CF LVAD implantation has emerged as an increasing concern, but little is known about the mechanism. Methods and Results: We retrospectively analyzed the 3-month hemodynamic and echocardiographic data from 38 consecutive patients who had received CF LVADs, and from 22 patients who had received PF LVADs. Late-onset RVF was defined as persistent right ventricular stroke work index (RVSWI) <4.0 g/m2 at any rotation speed and after saline infusion test at 5 weeks after implantation of CF LVAD. Patients with late-onset RVF had significantly impaired exercise tolerance indicated by shorter 6-min walking distance and lower peak V ̇O2, and worsened tricuspid regurgitation, together with enlargement of the RV under CF LVAD treatment (all P<0.05). Univariable analyses demonstrated that preoperative smaller LV diastolic diameter (LVDd) was the risk factor for late-onset RVF with a cutoff value of 64 mm calculated by ROC analysis (area under curve, 0.925). In contrast, there was no correlation between preoperative LVDd and postoperative RVSWI in the PF LVAD group, though their preoperative background was worse than that of the CF group. Conclusions: In the setting of preoperative small LVDd, CF LVAD may cause late-onset RVF by leftward shift of the interventricular septum.
UR - http://www.scopus.com/inward/record.url?scp=84894411589&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84894411589&partnerID=8YFLogxK
U2 - 10.1253/circj.CJ-13-1201
DO - 10.1253/circj.CJ-13-1201
M3 - Article
C2 - 24430596
AN - SCOPUS:84894411589
SN - 1346-9843
VL - 78
SP - 625
EP - 633
JO - Circulation Journal
JF - Circulation Journal
IS - 3
ER -