Abstract
A previously-reported concept of reactor cavity cooling system (RCCS) with passive safety features consists of two continuous closed regions: an ex-reactor pressure vessel region and a cooling region with a heat-transfer surface to ambient air. The RCCS uses a novel shape to efficiently remove the heat released from the reactor pressure vessel (RPV) through thermal radiation and natural convection. Employing air as a working fluid and ambient air as an ultimate heat sink, the novel RCCS design strongly reduces the possibility of losing the heat sink for decay-heat-removal during nuclear accidents including a station blackout. The RCCS could stably and passively remove the heat released from the RPV and the decay heat after reactor shutdown. The previously-reported heat-removal rate of the RCCS was approximately 3 (kW/m2). The heat flux from the RPV surface of the High Temperature engineering Test Reactor (HTTR) is almost in the same range; 1.23–2.46 (kW/m2). In this paper, the authors address an improvement of heat-removal capability by considering potential of heat leakage due to heat conduction through the RCCS wall aimed at increasing a thermal reactor power level. Under the assumption of doubling the RCCS wall heat transfer area, a heat-flux removed by the RCCS could be doubled, such as approximately 6.2 (kW/m2).
| Original language | English |
|---|---|
| Pages (from-to) | 201-206 |
| Number of pages | 6 |
| Journal | Annals of Nuclear Energy |
| Volume | 122 |
| DOIs | |
| Publication status | Published - Dec 2018 |
All Science Journal Classification (ASJC) codes
- Nuclear Energy and Engineering
Fingerprint
Dive into the research topics of 'Improvement of heat-removal capability using heat conduction on a novel reactor cavity cooling system (RCCS) design with passive safety features through radiation and natural convection'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS