TY - JOUR
T1 - Immunomagnetic flow cytometric detection of staphylococcal enterotoxin B in raw and dry milk
AU - Miyamoto, Takahisa
AU - Kamikado, Hideaki
AU - Kobayashi, Hiroshi
AU - Honjoh, Ken-ichi
AU - Iio, Masayoshi
PY - 2003/7/1
Y1 - 2003/7/1
N2 - A rapid and sensitive method for detection of staphylococcal enterotoxin B (SEB) in raw and dry milk samples with the use of antibody-based immunomagnetic separation (IMS) in conjunction with flow cytometry (FCM) was developed. Sheep anti-SEB immunoglobulin G (IgG) was immobilized on Dynabeads M-280. The SEB initially binds to the capturing antibody, which is bound on the magnetic beads. The rabbit anti-SEB IgG binds to the captured toxin and is further labeled with a Cy5-labeled goat anti-rabbit IgG antibody. The percentage of the beads that were fluorescent was measured by FCM. FCM was carried out for 1 min, and the data obtained were expressed as histograms for particle size (forward light scatter) and histograms for fluorescence intensity. A peak corresponding to the magnetic beads was clearly distinguished from a peak derived from contaminating particles in the sample solution. In the absence of SEB, about 10% of the beads emitted fluorescence. The percentage of fluorescent beads and the fluorescence intensity increased with increasing SEB concentrations. For this IMS-FCM assay, the lower limits of detection for SEB were estimated to be 0.01 and 0.25 ng/ml for buffer and milk samples, respectively.
AB - A rapid and sensitive method for detection of staphylococcal enterotoxin B (SEB) in raw and dry milk samples with the use of antibody-based immunomagnetic separation (IMS) in conjunction with flow cytometry (FCM) was developed. Sheep anti-SEB immunoglobulin G (IgG) was immobilized on Dynabeads M-280. The SEB initially binds to the capturing antibody, which is bound on the magnetic beads. The rabbit anti-SEB IgG binds to the captured toxin and is further labeled with a Cy5-labeled goat anti-rabbit IgG antibody. The percentage of the beads that were fluorescent was measured by FCM. FCM was carried out for 1 min, and the data obtained were expressed as histograms for particle size (forward light scatter) and histograms for fluorescence intensity. A peak corresponding to the magnetic beads was clearly distinguished from a peak derived from contaminating particles in the sample solution. In the absence of SEB, about 10% of the beads emitted fluorescence. The percentage of fluorescent beads and the fluorescence intensity increased with increasing SEB concentrations. For this IMS-FCM assay, the lower limits of detection for SEB were estimated to be 0.01 and 0.25 ng/ml for buffer and milk samples, respectively.
UR - http://www.scopus.com/inward/record.url?scp=0037770001&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0037770001&partnerID=8YFLogxK
U2 - 10.4315/0362-028X-66.7.1222
DO - 10.4315/0362-028X-66.7.1222
M3 - Article
C2 - 12870756
AN - SCOPUS:0037770001
SN - 0362-028X
VL - 66
SP - 1222
EP - 1226
JO - Journal of Food Protection
JF - Journal of Food Protection
IS - 7
ER -