TY - JOUR
T1 - Flow injection determination of anionic polyelectrolytes using an anionic surfactant-selective plasticized poly(vinyl chloride) membrane electrode detector
AU - Masadome, Takashi
AU - Imato, Toshihiko
AU - Itoh, Satoshi
AU - Asano, Yasukazu
PY - 1997
Y1 - 1997
N2 - A potentiometric flow injection method for the determination of anionic polyelectrolytes utilizing a flow-through type surfactant-selective electrode detector is described. The method is based on the detection of the concentration increase of anionic surfactant liberated from a reagent stream containing an ion associate between cationic polyelectrolyte, poly(diallyldimethylammonium chloride) and anionic surfactant, dodecylbenzenesulfonate, which is caused by the formation of a polyion complex between cationic and anionic polyelectrolytes. The response of the electrode detector as a peak-shaped signal was obtained for injected anionic polyelectrolyte samples. A linear relationship was found to exist between peak height and the logarithmic concentration of potassium poly (vinyl sulfate) (PVSK) with a slope of 30 mV decade-1 in a concentration range of 1.0 × 10-4 to 1.0 × 10-3 mol/L. Identical relationships were obtained for sodium alginate and carageenan (also anionic polyelectrolytes) as for PVSK but with a lower sensitivity. The detection limit for PVSK was 2.5 × 10-5 mol/L. The relative standard deviation for 5 injections of a 2.5 × 10-4 mol/L PVSK solution was 1.3% and the sampling rate was ca. 10 samples h-1.
AB - A potentiometric flow injection method for the determination of anionic polyelectrolytes utilizing a flow-through type surfactant-selective electrode detector is described. The method is based on the detection of the concentration increase of anionic surfactant liberated from a reagent stream containing an ion associate between cationic polyelectrolyte, poly(diallyldimethylammonium chloride) and anionic surfactant, dodecylbenzenesulfonate, which is caused by the formation of a polyion complex between cationic and anionic polyelectrolytes. The response of the electrode detector as a peak-shaped signal was obtained for injected anionic polyelectrolyte samples. A linear relationship was found to exist between peak height and the logarithmic concentration of potassium poly (vinyl sulfate) (PVSK) with a slope of 30 mV decade-1 in a concentration range of 1.0 × 10-4 to 1.0 × 10-3 mol/L. Identical relationships were obtained for sodium alginate and carageenan (also anionic polyelectrolytes) as for PVSK but with a lower sensitivity. The detection limit for PVSK was 2.5 × 10-5 mol/L. The relative standard deviation for 5 injections of a 2.5 × 10-4 mol/L PVSK solution was 1.3% and the sampling rate was ca. 10 samples h-1.
UR - http://www.scopus.com/inward/record.url?scp=0000684490&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0000684490&partnerID=8YFLogxK
U2 - 10.1007/s002160050271
DO - 10.1007/s002160050271
M3 - Article
AN - SCOPUS:0000684490
SN - 0937-0633
VL - 357
SP - 901
EP - 903
JO - Fresenius' Journal of Analytical Chemistry
JF - Fresenius' Journal of Analytical Chemistry
IS - 7
ER -