TY - JOUR
T1 - Feasibility and safety of intracorporeal esophagojejunostomy after laparoscopic total gastrectomy
T2 - Inverted T-shaped anastomosis using linear staplers
AU - Nagai, Eishi
AU - Ohuchida, Kenoki
AU - Nakata, Kohei
AU - Miyasaka, Yoshihiro
AU - Maeyama, Ryo
AU - Toma, Hiroki
AU - Shimizu, Shuji
AU - Tanaka, Masao
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013/5
Y1 - 2013/5
N2 - Background: Although laparoscopic distal gastrectomy has been widely accepted in clinical practice, laparoscopic total gastrectomy (LTG) is not yet familiar because of the difficulty in esophagojejunostomy. The purpose of this study was to evaluate perioperative and short-term outcomes of our procedure of intracorporeal gastrojejunostomy using linear staplers after LTG. Methods: Of 98 consecutive patients who underwent LTG for gastric cancer in our department between August 2002 and December 2010, 94 patients underwent esophagojejunostomy with a linear stapling device. After October 2007, we modified the esophagojejunostomy; ie, the most recent 57 patients underwent transection of the esophagus in the ventrodorsal direction and insertion of a linear stapler from the anterior wall of the Roux limb to the posterior wall so as to make an inverted T-shaped anastomosis. We evaluated the results in these 57 patients (recent group) and compared them with the results in the earlier 37 patients (early group). Results: The mean operative time in the recent group was 368 to 94.6 min, and the mean estimated blood loss was 57 to 33 g; both were comparable with those in the early group. Neither open conversion nor intraoperative complications were encountered. Two patients experienced anastomotic leakage in the earlier group, but anastomotic leakage did not occur in the recent group. No mortality was encountered. Conclusion: We herein report our procedure of intracorporeal gastrojejunostomy using linear staplers after LTG. Our procedure of esophagojejunostomy using linear staplers is safe and feasible and has acceptable morbidity.
AB - Background: Although laparoscopic distal gastrectomy has been widely accepted in clinical practice, laparoscopic total gastrectomy (LTG) is not yet familiar because of the difficulty in esophagojejunostomy. The purpose of this study was to evaluate perioperative and short-term outcomes of our procedure of intracorporeal gastrojejunostomy using linear staplers after LTG. Methods: Of 98 consecutive patients who underwent LTG for gastric cancer in our department between August 2002 and December 2010, 94 patients underwent esophagojejunostomy with a linear stapling device. After October 2007, we modified the esophagojejunostomy; ie, the most recent 57 patients underwent transection of the esophagus in the ventrodorsal direction and insertion of a linear stapler from the anterior wall of the Roux limb to the posterior wall so as to make an inverted T-shaped anastomosis. We evaluated the results in these 57 patients (recent group) and compared them with the results in the earlier 37 patients (early group). Results: The mean operative time in the recent group was 368 to 94.6 min, and the mean estimated blood loss was 57 to 33 g; both were comparable with those in the early group. Neither open conversion nor intraoperative complications were encountered. Two patients experienced anastomotic leakage in the earlier group, but anastomotic leakage did not occur in the recent group. No mortality was encountered. Conclusion: We herein report our procedure of intracorporeal gastrojejunostomy using linear staplers after LTG. Our procedure of esophagojejunostomy using linear staplers is safe and feasible and has acceptable morbidity.
UR - http://www.scopus.com/inward/record.url?scp=84876407909&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84876407909&partnerID=8YFLogxK
U2 - 10.1016/j.surg.2012.10.012
DO - 10.1016/j.surg.2012.10.012
M3 - Article
C2 - 23305598
AN - SCOPUS:84876407909
SN - 0039-6060
VL - 153
SP - 732
EP - 738
JO - Surgery (United States)
JF - Surgery (United States)
IS - 5
ER -