TY - JOUR
T1 - Extracellular volume fraction determined by dual-layer spectral detector CT
T2 - Possible role in predicting the efficacy of preoperative neoadjuvant chemotherapy in pancreatic ductal adenocarcinoma
AU - Fujita, Nobuhiro
AU - Ushijima, Yasuhiro
AU - Itoyama, Masahiro
AU - Okamoto, Daisuke
AU - Ishimatsu, Keisuke
AU - Wada, Noriaki
AU - Takao, Seiichiro
AU - Murayama, Ryo
AU - Fujimori, Nao
AU - Nakata, Kohei
AU - Nakamura, Masafumi
AU - Yamamoto, Takeo
AU - Oda, Yoshinao
AU - Ishigami, Kousei
N1 - Publisher Copyright:
© 2023 Elsevier B.V.
PY - 2023/5
Y1 - 2023/5
N2 - Purpose: To clarify the relationship between extracellular volume (ECV) measured by dual-energy CT (DECT) and efficacy of preoperative neoadjuvant chemotherapy (NAC) in patients with pancreatic ductal adenocarcinoma (PDAC), as compared with single-energy CT (SECT). Methods: We enrolled 67 patients with PDAC who underwent dynamic contrast-enhanced CT with a dual-energy CT system prior to NAC. Attenuation values were measured on unenhanced and the equilibrium-phase 120-kVp equivalent CT images for PDAC and the aorta. ΔHU-tumor, ΔHU-tumor/ΔHU-aorta, and SECT-ECV were calculated. Iodine densities of the tumor and aorta were measured in the equilibrium phase, and DECT-ECV of the tumor was calculated. Response to NAC was evaluated and the correlation between imaging parameters and response to NAC was statistically assessed. Results: Tumor DECT-ECVs were significantly lower in the response group (n = 7) than in the non-response group (n = 60), with most significant difference (p = 0.0104). DECT-ECV showed highest diagnostic value with an Az value of 0.798. When using the optimal cut off value of DECT-ECV (<26.0 %), sensitivity, specificity, accuracy, positive predictive value, and negative value for predicting response group were 71.4 %, 85.0 %, 83.6 %, 35.7 % and 96.2 %, respectively. Conclusion: PDAC with lower DECT-ECV can potentially show better response to NAC. DECT-ECV might be a useful biomarker for predicting response to NAC in patients with PDAC.
AB - Purpose: To clarify the relationship between extracellular volume (ECV) measured by dual-energy CT (DECT) and efficacy of preoperative neoadjuvant chemotherapy (NAC) in patients with pancreatic ductal adenocarcinoma (PDAC), as compared with single-energy CT (SECT). Methods: We enrolled 67 patients with PDAC who underwent dynamic contrast-enhanced CT with a dual-energy CT system prior to NAC. Attenuation values were measured on unenhanced and the equilibrium-phase 120-kVp equivalent CT images for PDAC and the aorta. ΔHU-tumor, ΔHU-tumor/ΔHU-aorta, and SECT-ECV were calculated. Iodine densities of the tumor and aorta were measured in the equilibrium phase, and DECT-ECV of the tumor was calculated. Response to NAC was evaluated and the correlation between imaging parameters and response to NAC was statistically assessed. Results: Tumor DECT-ECVs were significantly lower in the response group (n = 7) than in the non-response group (n = 60), with most significant difference (p = 0.0104). DECT-ECV showed highest diagnostic value with an Az value of 0.798. When using the optimal cut off value of DECT-ECV (<26.0 %), sensitivity, specificity, accuracy, positive predictive value, and negative value for predicting response group were 71.4 %, 85.0 %, 83.6 %, 35.7 % and 96.2 %, respectively. Conclusion: PDAC with lower DECT-ECV can potentially show better response to NAC. DECT-ECV might be a useful biomarker for predicting response to NAC in patients with PDAC.
KW - Dual-energy CT
KW - Extracellular volume
KW - Neoadjuvant chemotherapy
KW - Pancreatic ductal adenocarcinoma
UR - http://www.scopus.com/inward/record.url?scp=85149786862&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85149786862&partnerID=8YFLogxK
U2 - 10.1016/j.ejrad.2023.110756
DO - 10.1016/j.ejrad.2023.110756
M3 - Article
C2 - 36907069
AN - SCOPUS:85149786862
SN - 0720-048X
VL - 162
JO - European Journal of Radiology
JF - European Journal of Radiology
M1 - 110756
ER -