TY - JOUR
T1 - Evaluating Energy-Efficiency of DRAM Channel Interleaving Schemes for Multithreaded Programs
AU - Imamura, Satoshi
AU - Yasui, Yuichiro
AU - Inoue, Koji
AU - Ono, Takatsugu
AU - Sasaki, Hiroshi
AU - Fujisawa, Katsuki
PY - 2018
Y1 - 2018
N2 - The power consumption of server platforms has been increasing as the amount of hardware resources equipped on them is increased. Especially, the capacity of DRAM continues to grow, and it is not rare that DRAM consumes higher power than processors on modern servers. Therefore, a reduction in the DRAM energy consumption is a critical challenge to reduce the system-level energy consumption. Although it is well known that improving row buffer locality(RBL) and bank-level parallelism (BLP) is effective to reduce the DRAM energy consumption, our preliminary evaluation on a real server demonstrates that RBL is generally low across 15 multithreaded benchmarks. In this paper, we investigate the memory access patterns of these benchmarks using a simulator and observe that cache line-grained channel interleaving schemes, which are widely applied to modern servers including multiple memory channels, hurt the RBL each of the benchmarks potentially possesses. In order to address this problem, we focus on a row-grained channel interleaving scheme and compare it with three cache line-grained schemes. Our evaluation shows that it reduces the DRAM energy consumption by 16.7%, 12.3%, and 5.5% on average (up to 34.7%, 28.2%, and 12.0%) compared to the other schemes, respectively.
AB - The power consumption of server platforms has been increasing as the amount of hardware resources equipped on them is increased. Especially, the capacity of DRAM continues to grow, and it is not rare that DRAM consumes higher power than processors on modern servers. Therefore, a reduction in the DRAM energy consumption is a critical challenge to reduce the system-level energy consumption. Although it is well known that improving row buffer locality(RBL) and bank-level parallelism (BLP) is effective to reduce the DRAM energy consumption, our preliminary evaluation on a real server demonstrates that RBL is generally low across 15 multithreaded benchmarks. In this paper, we investigate the memory access patterns of these benchmarks using a simulator and observe that cache line-grained channel interleaving schemes, which are widely applied to modern servers including multiple memory channels, hurt the RBL each of the benchmarks potentially possesses. In order to address this problem, we focus on a row-grained channel interleaving scheme and compare it with three cache line-grained schemes. Our evaluation shows that it reduces the DRAM energy consumption by 16.7%, 12.3%, and 5.5% on average (up to 34.7%, 28.2%, and 12.0%) compared to the other schemes, respectively.
U2 - 10.1587/transinf.2017EDP7296
DO - 10.1587/transinf.2017EDP7296
M3 - Article
SN - 0916-8532
VL - 101
SP - 2247
EP - 2257
JO - IEICE Transactions on Information and Systems
JF - IEICE Transactions on Information and Systems
IS - 9
ER -