TY - GEN
T1 - Estimation of intraoperative blood flow during liver RF ablation using a finite element method-based biomechanical simulation
AU - Watanabe, Hiroki
AU - Yamazaki, Nozomu
AU - Kobayashi, Yo
AU - Miyashita, Tomoyuki
AU - Ohdaira, Takeshi
AU - Hashizume, Makoto
AU - Fujie, Masakatsu G.
PY - 2011
Y1 - 2011
N2 - Radiofrequency ablation is increasingly being used for liver cancer because it is a minimally invasive treatment method. However, it is difficult for the operators to precisely control the formation of coagulation zones because of the cooling effect of capillary vessels. To overcome this limitation, we have proposed a model-based robotic ablation system using a real-time numerical simulation to analyze temperature distributions in the target organ. This robot can determine the adequate amount of electric power supplied to the organ based on real-time temperature information reflecting the cooling effect provided by the simulator. The objective of this study was to develop a method to estimate the intraoperative rate of blood flow in the target organ to determine temperature distribution. In this paper, we propose a simulation-based method to estimate the rate of blood flow. We also performed an in vitro study to validate the proposed method by estimating the rate of blood flow in a hog liver. The experimental results revealed that the proposed method can be used to estimate the rate of blood flow in an organ.
AB - Radiofrequency ablation is increasingly being used for liver cancer because it is a minimally invasive treatment method. However, it is difficult for the operators to precisely control the formation of coagulation zones because of the cooling effect of capillary vessels. To overcome this limitation, we have proposed a model-based robotic ablation system using a real-time numerical simulation to analyze temperature distributions in the target organ. This robot can determine the adequate amount of electric power supplied to the organ based on real-time temperature information reflecting the cooling effect provided by the simulator. The objective of this study was to develop a method to estimate the intraoperative rate of blood flow in the target organ to determine temperature distribution. In this paper, we propose a simulation-based method to estimate the rate of blood flow. We also performed an in vitro study to validate the proposed method by estimating the rate of blood flow in a hog liver. The experimental results revealed that the proposed method can be used to estimate the rate of blood flow in an organ.
UR - http://www.scopus.com/inward/record.url?scp=84861684958&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84861684958&partnerID=8YFLogxK
U2 - 10.1109/IEMBS.2011.6091745
DO - 10.1109/IEMBS.2011.6091745
M3 - Conference contribution
C2 - 22256059
AN - SCOPUS:84861684958
SN - 9781424441211
T3 - Proceedings of the Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS
SP - 7441
EP - 7445
BT - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
T2 - 33rd Annual International Conference of the IEEE Engineering in Medicine and Biology Society, EMBS 2011
Y2 - 30 August 2011 through 3 September 2011
ER -