TY - JOUR
T1 - Effect of loaded orthodontic miniscrew implant on compressive stresses in adjacent periodontal ligament
AU - Albogha, Mhd Hassan
AU - Takahashi, Ichiro
N1 - Publisher Copyright:
© 2019 by The EH Angle Education and Research Foundation, Inc.
PY - 2019/3
Y1 - 2019/3
N2 - Objectives: To describe the relationship between the proximity of miniscrew implants (MSIs) to the periodontal ligament (PDL) and stress in the PDL under different load magnitudes and different bone properties. Materials and Methods: Sixteen subject-specific finite element models of the region of the maxillary first molar and second premolar were developed using computed tomography images of four patients. For each patient, an MSI surface model derived from micro-computed tomography was placed at four different distances from the premolar PDL. Finite element analysis was conducted with mesial load on the MSI, increasing from 1 N to 4 N. Peak absolute compression stress (CS) was calculated at each 1 N step. Stepwise multiple regression modeling was conducted to explain compressive stress by proximity, load magnitude, and bone properties. Results: The multiple regression model explained 83.47% of the variation of CS and included all three factors: proximity, load magnitude, and bone properties. The model expected significant interaction between the bone properties and load magnitude, implying that strong bone properties could be associated with significant increases in CS at small increases in load. Conclusions: To ensure the safety of adjacent roots, MSIs should be placed at least 1 mm from the roots. Assessment of alveolar bone properties is recommended when the use of MSI is intended, as some patients may present with strong bone properties and thereby a high risk of MSI-induced root resorption.
AB - Objectives: To describe the relationship between the proximity of miniscrew implants (MSIs) to the periodontal ligament (PDL) and stress in the PDL under different load magnitudes and different bone properties. Materials and Methods: Sixteen subject-specific finite element models of the region of the maxillary first molar and second premolar were developed using computed tomography images of four patients. For each patient, an MSI surface model derived from micro-computed tomography was placed at four different distances from the premolar PDL. Finite element analysis was conducted with mesial load on the MSI, increasing from 1 N to 4 N. Peak absolute compression stress (CS) was calculated at each 1 N step. Stepwise multiple regression modeling was conducted to explain compressive stress by proximity, load magnitude, and bone properties. Results: The multiple regression model explained 83.47% of the variation of CS and included all three factors: proximity, load magnitude, and bone properties. The model expected significant interaction between the bone properties and load magnitude, implying that strong bone properties could be associated with significant increases in CS at small increases in load. Conclusions: To ensure the safety of adjacent roots, MSIs should be placed at least 1 mm from the roots. Assessment of alveolar bone properties is recommended when the use of MSI is intended, as some patients may present with strong bone properties and thereby a high risk of MSI-induced root resorption.
UR - http://www.scopus.com/inward/record.url?scp=85060954240&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85060954240&partnerID=8YFLogxK
U2 - 10.2319/122017-873.1
DO - 10.2319/122017-873.1
M3 - Article
C2 - 30230377
AN - SCOPUS:85060954240
SN - 0003-3219
VL - 89
SP - 235
EP - 241
JO - Angle Orthodontist
JF - Angle Orthodontist
IS - 2
ER -