Abstract
We produced a 915 MHz ECR plasma with TM01 microwaves for different magnetic flux density distributions and examined the radial profiles of the ion saturation current as a function of pressure and power. It was found that the 915 MHz ECR plasma is uniform over 200 mm in diameter around the L-cutoff density and when a diverging magnetic field is used, a low electron temperature plasma is realized.
| Original language | English |
|---|---|
| Pages (from-to) | 123-127 |
| Number of pages | 5 |
| Journal | Vacuum |
| Volume | 87 |
| DOIs | |
| Publication status | Published - 2013 |
All Science Journal Classification (ASJC) codes
- Instrumentation
- Condensed Matter Physics
- Surfaces, Coatings and Films
Fingerprint
Dive into the research topics of 'Development of a 915 MHz ECR plasma source'. Together they form a unique fingerprint.Cite this
- APA
- Standard
- Harvard
- Vancouver
- Author
- BIBTEX
- RIS