TY - JOUR
T1 - Determination of minute amounts of D-leucine in various brain regions of rat and mouse using column-switching high-performance liquid chromatography
AU - Inoue, Tomomi
AU - Hamase, Kenji
AU - Morikawa, Akiko
AU - Zaitsu, Kiyoshi
N1 - Copyright:
Copyright 2007 Elsevier B.V., All rights reserved.
PY - 2000/7/7
Y1 - 2000/7/7
N2 - A highly sensitive method for the determination of minute amounts of D-Leu in biological samples was developed. For accurate and sensitive determination, a column-switching system using a micro ODS column and a chiral column was adopted. After pre-column derivatization of D- and L-Leu with NBD-F, the derivatives of the enantiomers were purified on a micro ODS column as a DL mixture. The eluted DL-Leu was then introduced to the chiral column, and each enantiomer was determined. The calibration curve for D-Leu, which was constructed by adding known amounts of D-Leu to a rat hippocampus, was linear from 1 to 1000 fmol (r>0.999), and the detection limit of added D-Leu was 1 fmol (S/N=5). Within-day and day-to-day precisions of D-Leu determination using the same homogenate of rat hippocampus were 5.11 and 5.25% (RSD), respectively. The content of D-Leu in rat hippocampus was 0.69 nmol/g wet tissue (the percentage of D-enantiomer for total Leu was 0.97%), which was consistent with the reported value. The distribution of D-Leu in mouse brain was also investigated, and the presence of D-Leu in various regions of the mammalian brain was first observed. Copyright (C) 2000 Elsevier Science B.V.
AB - A highly sensitive method for the determination of minute amounts of D-Leu in biological samples was developed. For accurate and sensitive determination, a column-switching system using a micro ODS column and a chiral column was adopted. After pre-column derivatization of D- and L-Leu with NBD-F, the derivatives of the enantiomers were purified on a micro ODS column as a DL mixture. The eluted DL-Leu was then introduced to the chiral column, and each enantiomer was determined. The calibration curve for D-Leu, which was constructed by adding known amounts of D-Leu to a rat hippocampus, was linear from 1 to 1000 fmol (r>0.999), and the detection limit of added D-Leu was 1 fmol (S/N=5). Within-day and day-to-day precisions of D-Leu determination using the same homogenate of rat hippocampus were 5.11 and 5.25% (RSD), respectively. The content of D-Leu in rat hippocampus was 0.69 nmol/g wet tissue (the percentage of D-enantiomer for total Leu was 0.97%), which was consistent with the reported value. The distribution of D-Leu in mouse brain was also investigated, and the presence of D-Leu in various regions of the mammalian brain was first observed. Copyright (C) 2000 Elsevier Science B.V.
UR - http://www.scopus.com/inward/record.url?scp=0034617473&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0034617473&partnerID=8YFLogxK
U2 - 10.1016/S0378-4347(00)00244-9
DO - 10.1016/S0378-4347(00)00244-9
M3 - Article
C2 - 10985585
AN - SCOPUS:0034617473
SN - 1387-2273
VL - 744
SP - 213
EP - 219
JO - Journal of Chromatography B: Biomedical Sciences and Applications
JF - Journal of Chromatography B: Biomedical Sciences and Applications
IS - 1
ER -