TY - JOUR
T1 - Detection of weak ligand interactions of leukocyte Ig-like receptor B1 by fluorescence correlation spectroscopy
AU - Kuroki, Kimiko
AU - Kobayashi, Sayoko
AU - Shiroishi, Mitsunori
AU - Kajikawa, Mizuho
AU - Okamoto, Naoaki
AU - Kohda, Daisuke
AU - Maenaka, Katsumi
N1 - Funding Information:
MS was supported by a JSPS postdoctoral fellowship for young researchers. KM and DK were supported in part by the Ministry of Education, Science, Sports, Culture and Technology of Japan, and the Protein 3000 project. KK, MK and KM were supported by the Japan Bio-oriented Technology Research Advancement Institute (BRAIN).
PY - 2007/3/30
Y1 - 2007/3/30
N2 - Fluorescence correlation spectroscopy (FCS) can directly and quickly detect the translational diffusion of individual fluorescence-labeled molecules in solutions. Although FCS analyses for protein-protein interactions have been performed, the very weak interactions generally observed in cell-cell recognition of the immune system have not been examined in detail. Here, we report the FCS analysis for low-affinity and fast-kinetic binding (Kd greater than μM range) of the human inhibitory immune cell surface receptor, leukocyte immunoglobulin-like receptor B1 (LILRB1), to its ligands, MHC (major histocompatibility complex) class I molecules (MHCIs) by using the single-molecule FCS detection system which requires only a small amount of sample. Since the random labeling technique for LILRB1 disturbed the MHCI binding, we performed site-specific labeling of LILRB1 by introducing a cysteine residue at the C-terminus, which could be covalently attached with the fluorescence reagent, Alexa647. This technique can be applied to other type I membrane receptors. The low-affinity binding of LILRB1-Alexa647 to MHCIs (HLA-Cw4, and -G1) was detected by FCS, even though non-labeled MHCIs were only twice as big as the labeled LILRB1. Their dissociation constants (7.5 μM (HLA-Cw4) and 5.7 μM (HLA-G1)) could be determined and were consistent with surface plasmon resonance (SPR) data. These results indicate that the single-molecule FCS detection system is capable of analyzing the binding characteristics of immune cell surface receptors even in difficult cases such as (1) small amount of protein samples, (2) small difference in molecular weight and (3) weak affinity. Therefore, it is a powerful tool for characterization and high throughput inhibitor screening of a wide variety of cell-cell recognition receptors involved in immunologically relevant events.
AB - Fluorescence correlation spectroscopy (FCS) can directly and quickly detect the translational diffusion of individual fluorescence-labeled molecules in solutions. Although FCS analyses for protein-protein interactions have been performed, the very weak interactions generally observed in cell-cell recognition of the immune system have not been examined in detail. Here, we report the FCS analysis for low-affinity and fast-kinetic binding (Kd greater than μM range) of the human inhibitory immune cell surface receptor, leukocyte immunoglobulin-like receptor B1 (LILRB1), to its ligands, MHC (major histocompatibility complex) class I molecules (MHCIs) by using the single-molecule FCS detection system which requires only a small amount of sample. Since the random labeling technique for LILRB1 disturbed the MHCI binding, we performed site-specific labeling of LILRB1 by introducing a cysteine residue at the C-terminus, which could be covalently attached with the fluorescence reagent, Alexa647. This technique can be applied to other type I membrane receptors. The low-affinity binding of LILRB1-Alexa647 to MHCIs (HLA-Cw4, and -G1) was detected by FCS, even though non-labeled MHCIs were only twice as big as the labeled LILRB1. Their dissociation constants (7.5 μM (HLA-Cw4) and 5.7 μM (HLA-G1)) could be determined and were consistent with surface plasmon resonance (SPR) data. These results indicate that the single-molecule FCS detection system is capable of analyzing the binding characteristics of immune cell surface receptors even in difficult cases such as (1) small amount of protein samples, (2) small difference in molecular weight and (3) weak affinity. Therefore, it is a powerful tool for characterization and high throughput inhibitor screening of a wide variety of cell-cell recognition receptors involved in immunologically relevant events.
UR - http://www.scopus.com/inward/record.url?scp=33847637989&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=33847637989&partnerID=8YFLogxK
U2 - 10.1016/j.jim.2006.11.009
DO - 10.1016/j.jim.2006.11.009
M3 - Article
C2 - 17217953
AN - SCOPUS:33847637989
SN - 0022-1759
VL - 320
SP - 172
EP - 176
JO - Journal of Immunological Methods
JF - Journal of Immunological Methods
IS - 1-2
ER -