T1 - Comparative assessment of condensation and pool boiling heat transfer on horizontal plain single tubes for R1234ze(E), R1234ze(Z), and R1233zd(E)
AU - Nagata, Ryuichi
AU - Kondou, Chieko
AU - Koyama, Shigeru
N1 - Funding Information:
The present study is sponsored by the project on the “Development of High Efficiency and Non-Freon Air Conditioning Systems” of the New Energy and Industrial Technology Development Organization (NEDO) Japan. The tested R245fa and R1233zd(E) were kindly supplied by Central Glass Co., Ltd., Japan. Appendix A
Publisher Copyright:
© 2015 Elsevier Ltd and International Institute of Refrigeration. All rights reserved.
PY - 2016/3/1
Y1 - 2016/3/1
N2 - The low-global warming potential (GWP) refrigerant of R1234ze(E) is considered to be a prospective alternative to conventional R134a for car air conditioners, whereas the isomer R1234ze(Z) and R1233zd(E) are anticipated to be the low-GWP alternatives to R245fa used in high-temperature heat pumps and organic Rankine cycles. The free convective condensation and pool boiling heat transfer coefficients (HTCs) of these refrigerants on a horizontal smooth tube made of copper with an outer diameter of 19.12 mm are comparatively assessed in this study. For the condensation experiment, the measured HTCs of R1234ze(E) and R1234ze(Z) agree with the theoretical HTC within ±10%. However, the experimental HTC of R1233zd(E) is biased by +25% on average to the theoretical HTC. This suggests the considerable estimation error in R1233zd(E) transport properties. From the pool boiling observations, the role of surface tension on nucleate boiling was identified by the bubble behavior. The experimental boiling HTC closely agrees with the HTC calculated by Ribatski and Jabardo (2003).
AB - The low-global warming potential (GWP) refrigerant of R1234ze(E) is considered to be a prospective alternative to conventional R134a for car air conditioners, whereas the isomer R1234ze(Z) and R1233zd(E) are anticipated to be the low-GWP alternatives to R245fa used in high-temperature heat pumps and organic Rankine cycles. The free convective condensation and pool boiling heat transfer coefficients (HTCs) of these refrigerants on a horizontal smooth tube made of copper with an outer diameter of 19.12 mm are comparatively assessed in this study. For the condensation experiment, the measured HTCs of R1234ze(E) and R1234ze(Z) agree with the theoretical HTC within ±10%. However, the experimental HTC of R1233zd(E) is biased by +25% on average to the theoretical HTC. This suggests the considerable estimation error in R1233zd(E) transport properties. From the pool boiling observations, the role of surface tension on nucleate boiling was identified by the bubble behavior. The experimental boiling HTC closely agrees with the HTC calculated by Ribatski and Jabardo (2003).
UR - http://www.scopus.com/inward/record.url?scp=84955248371&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84955248371&partnerID=8YFLogxK
U2 - 10.1016/j.ijrefrig.2015.11.002
DO - 10.1016/j.ijrefrig.2015.11.002
M3 - Article
AN - SCOPUS:84955248371
SN - 0140-7007
VL - 63
SP - 157
EP - 170
JO - International Journal of Refrigeration
JF - International Journal of Refrigeration
ER -