T1 - Clinical evaluation and feasibility of changing intraoperative visibility with a novel viewing filter system for human eye
AU - Enaida, Hiroshi
AU - Ikeda, Yasuhiro
AU - Yoshida, Shigeo
AU - Nakao, Shintaro
AU - Hachisuka, Yoshiyuki
AU - Fujita, Katsumi
AU - Oshima, Yusuke
AU - Kadonosono, Kazuaki
AU - Matsui, Takaaki
AU - Ishibashi, Tatsuro
N1 - Copyright:
Copyright 2013 Elsevier B.V., All rights reserved.
PY - 2013/10
Y1 - 2013/10
N2 - PURPOSE:: The study was conducted to develop a new viewing system as a clinical prototype that enables visibility during surgery. METHODS:: The system was composed of several filters attached to the microscope. This nonrandomized, retrospective, observational case series study involved 33 eyes from 32 patients who presented with various diseases and underwent surgery. The authors evaluated the changes in visualization focusing on controlling intraoperative visibility under air infusion and enhancing Brilliant Blue G staining focusing a sharp-cut filter Y (SCY). Visibility was compared under various surgical conditions, including cataract surgery, both with and without this system. Quantitative analysis of changes in intraoperative reflection including halation under air infusion and Brilliant Blue G intensity was carried out using the International Commission on Illumination 1976 (L*, a*, b*) color space method. RESULTS:: A SCY reduced the reflection and halation by a maximum of 69.6%, when compared with use of no filter under air infusion (P < 0.01). The color difference between Brilliant Blue G-stained and nonstained areas was improved by 127.8% relative to values with no filter and using SCY (P < 0.01) in macular hole cases. Furthermore, in cataract surgery with corneal opacity, improvement of visibility was observed by SCY insertion. CONCLUSION:: The system improved intraoperative visibility under air infusion and the Brilliant Blue G staining intensity by use of SCY during vitrectomy.
AB - PURPOSE:: The study was conducted to develop a new viewing system as a clinical prototype that enables visibility during surgery. METHODS:: The system was composed of several filters attached to the microscope. This nonrandomized, retrospective, observational case series study involved 33 eyes from 32 patients who presented with various diseases and underwent surgery. The authors evaluated the changes in visualization focusing on controlling intraoperative visibility under air infusion and enhancing Brilliant Blue G staining focusing a sharp-cut filter Y (SCY). Visibility was compared under various surgical conditions, including cataract surgery, both with and without this system. Quantitative analysis of changes in intraoperative reflection including halation under air infusion and Brilliant Blue G intensity was carried out using the International Commission on Illumination 1976 (L*, a*, b*) color space method. RESULTS:: A SCY reduced the reflection and halation by a maximum of 69.6%, when compared with use of no filter under air infusion (P < 0.01). The color difference between Brilliant Blue G-stained and nonstained areas was improved by 127.8% relative to values with no filter and using SCY (P < 0.01) in macular hole cases. Furthermore, in cataract surgery with corneal opacity, improvement of visibility was observed by SCY insertion. CONCLUSION:: The system improved intraoperative visibility under air infusion and the Brilliant Blue G staining intensity by use of SCY during vitrectomy.
UR - http://www.scopus.com/inward/record.url?scp=84885019212&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84885019212&partnerID=8YFLogxK
U2 - 10.1097/IAE.0b013e318289921f
DO - 10.1097/IAE.0b013e318289921f
M3 - Article
C2 - 23619631
AN - SCOPUS:84885019212
SN - 0275-004X
VL - 33
SP - 1923
EP - 1930
JO - Retina
JF - Retina
IS - 9
ER -