TY - JOUR
T1 - Chronological changes in the eighth cranial nerve compound action potential (CAP) in experimental endolymphatic hydrops
T2 - the effects of altering the polarity of click sounds.
AU - Morizono, Tetsuo
AU - Kondo, Tsuyoshi
AU - Yamano, Takafumi
AU - Miyagi, Morimichi
AU - Shiraishi, Kimio
PY - 2009/2/1
Y1 - 2009/2/1
N2 - CONCLUSION: Using a guinea pig model of experimental endolymphatic hydrops, click sounds of altered polarity showed different latencies and amplitudes in hydropic compared with normal cochleae. Latency changes appeared as early as 1 week after endolymphatic obstruction. This method can help diagnose endolymphatic hydrops. OBJECTIVE: The goal of the study was to develop an objective electrophysiological diagnosis of endolymphatic hydrops. MATERIALS AND METHODS: Endolymphatic hydrops were created surgically in guinea pigs. The latency and the amplitude of the eighth cranial nerve compound action potential (CAP) for click sounds of altered polarity were measured up to 8 weeks after the surgery. RESULTS: At early stages after surgery, the latency for condensation clicks became longer, and at later stages the latencies for both condensation and rarefaction became longer. The discrepancy in the latencies for rarefaction and condensation click sounds (rarefaction minus condensation) became larger by the first week after surgery, but no further discrepancy occurred thereafter. Compared with latency changes, amplitude changes in the CAP were rapid and progressive following surgery, suggesting ongoing damage to hair cells.
AB - CONCLUSION: Using a guinea pig model of experimental endolymphatic hydrops, click sounds of altered polarity showed different latencies and amplitudes in hydropic compared with normal cochleae. Latency changes appeared as early as 1 week after endolymphatic obstruction. This method can help diagnose endolymphatic hydrops. OBJECTIVE: The goal of the study was to develop an objective electrophysiological diagnosis of endolymphatic hydrops. MATERIALS AND METHODS: Endolymphatic hydrops were created surgically in guinea pigs. The latency and the amplitude of the eighth cranial nerve compound action potential (CAP) for click sounds of altered polarity were measured up to 8 weeks after the surgery. RESULTS: At early stages after surgery, the latency for condensation clicks became longer, and at later stages the latencies for both condensation and rarefaction became longer. The discrepancy in the latencies for rarefaction and condensation click sounds (rarefaction minus condensation) became larger by the first week after surgery, but no further discrepancy occurred thereafter. Compared with latency changes, amplitude changes in the CAP were rapid and progressive following surgery, suggesting ongoing damage to hair cells.
UR - http://www.scopus.com/inward/record.url?scp=66149143998&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=66149143998&partnerID=8YFLogxK
M3 - Article
C2 - 19221904
SN - 0365-5237
SP - 32
EP - 37
JO - Acta oto-laryngologica. Supplementum
JF - Acta oto-laryngologica. Supplementum
IS - 560
ER -