TY - JOUR
T1 - Cementless total hip arthroplasty for patients previously treated with femoral osteotomy for hip dysplasia
T2 - the incidence of periprosthetic fracture
AU - Ohishi, Masanobu
AU - Nakashima, Yasuharu
AU - Yamamoto, Takuaki
AU - Motomura, Goro
AU - Fukushi, Jun ichi
AU - Hamai, Satoshi
AU - Kohno, Yusuke
AU - Iwamoto, Yukihide
N1 - Publisher Copyright:
© 2015, SICOT aisbl.
PY - 2016/8/1
Y1 - 2016/8/1
N2 - Purpose: Femur deformities can make stem fixation difficult in total hip arthroplasty (THA). We report the clinical results of cementless THA using a press-fit stem in patients who had previously undergone femoral osteotomy for hip dysplasia. Methods: The subjects included 66 hips in 64 patients, with the mean follow-up period of 7.3 years. THA was performed at a mean period of 17.1 years after intertrochanteric femoral osteotomy. Valgus osteotomy was performed in 42 hips, and varus osteotomy in 24. Clinical results were evaluated by using the Merle d’Aubigne-Postel score. Implant survival was determined with revision as the end point, and any related complications were investigated. Results: The Merle d’Aubigne-Postel score improved from 9.4 to 16.1 at the final follow-up, without any implant loosening. However, periprosthetic femoral fractures were observed in four hips (6.0 %), one intra-operatively and three within three weeks after THA. Among these cases, three hips previously had varus osteotomy (12.5 %) and one hip had valgus osteotomy (2.3 %). Two hips were revised with full porous stems and circumferential wiring. The five and ten year cumulative survivorship rates were 97 % (range, 88.8–99.3 %) and 97 % (88.8–99.3 %), respectively. Conclusions: Although the use of a press-fit cementless stem yielded acceptable results in most of the patients, perioperative femoral fracture was a major complication especially in the patients previously treated with intertrochanteric varus osteotomy. Careful planning and implant selection could be emphasized for these cases.
AB - Purpose: Femur deformities can make stem fixation difficult in total hip arthroplasty (THA). We report the clinical results of cementless THA using a press-fit stem in patients who had previously undergone femoral osteotomy for hip dysplasia. Methods: The subjects included 66 hips in 64 patients, with the mean follow-up period of 7.3 years. THA was performed at a mean period of 17.1 years after intertrochanteric femoral osteotomy. Valgus osteotomy was performed in 42 hips, and varus osteotomy in 24. Clinical results were evaluated by using the Merle d’Aubigne-Postel score. Implant survival was determined with revision as the end point, and any related complications were investigated. Results: The Merle d’Aubigne-Postel score improved from 9.4 to 16.1 at the final follow-up, without any implant loosening. However, periprosthetic femoral fractures were observed in four hips (6.0 %), one intra-operatively and three within three weeks after THA. Among these cases, three hips previously had varus osteotomy (12.5 %) and one hip had valgus osteotomy (2.3 %). Two hips were revised with full porous stems and circumferential wiring. The five and ten year cumulative survivorship rates were 97 % (range, 88.8–99.3 %) and 97 % (88.8–99.3 %), respectively. Conclusions: Although the use of a press-fit cementless stem yielded acceptable results in most of the patients, perioperative femoral fracture was a major complication especially in the patients previously treated with intertrochanteric varus osteotomy. Careful planning and implant selection could be emphasized for these cases.
UR - http://www.scopus.com/inward/record.url?scp=84942015252&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84942015252&partnerID=8YFLogxK
U2 - 10.1007/s00264-015-2992-3
DO - 10.1007/s00264-015-2992-3
M3 - Article
C2 - 26384984
AN - SCOPUS:84942015252
SN - 0341-2695
VL - 40
SP - 1601
EP - 1606
JO - International Orthopaedics
JF - International Orthopaedics
IS - 8
ER -