TY - JOUR
T1 - Cardiac energetics analysis after aortic valve replacement with 16-mm ATS mechanical valve
AU - Ushijima, Tomoki
AU - Tanoue, Yoshihisa
AU - Uchida, Takayuki
AU - Matsuyama, Sho
AU - Matsumoto, Takashi
AU - Tominaga, Ryuji
N1 - Publisher Copyright:
© 2014, The Japanese Society for Artificial Organs.
PY - 2014/9
Y1 - 2014/9
N2 - The 16-mm ATS mechanical valve is one of the smallest prosthetic valves used for aortic valve replacement (AVR) in patients with a very small aortic annulus, and its clinical outcomes are reportedly satisfactory. Here, we analyzed the left ventricular (LV) performance after AVR with the 16-mm ATS mechanical valve, based on the concept of cardiac energetics analysis. Eleven patients who underwent AVR with the 16-mm ATS mechanical valve were enrolled in this study. All underwent echocardiographic examination at three time points: before AVR, approximately 1 month after AVR, and approximately 1 year after AVR. LV contractility (end-systolic elastance [Ees]), afterload (effective arterial elastance [Ea]), and efficiency (ventriculoarterial coupling [Ea/Ees] and the stroke work to pressure–volume area ratio [SW/PVA]) were noninvasively measured by echocardiographic data and blood pressure measurement. Ees transiently decreased after AVR and then recovered to the pre-AVR level at the one-year follow-up. Ea significantly decreased in a stepwise manner. Consequently, Ea/Ees and SW/PVA were also significantly improved at the one-year follow-up compared with those before AVR. The midterm LV performance after AVR with the 16-mm ATS mechanical valve was satisfactory. AVR with the 16-mm ATS mechanical valve is validated as an effective treatment for patients with a very small aortic annulus. The cardiac energetics variables, coupling with the conventional hemodynamic variables, can contribute to a better understanding of the patients’ clinical conditions, and those may serve as promising indices of the cardiac function.
AB - The 16-mm ATS mechanical valve is one of the smallest prosthetic valves used for aortic valve replacement (AVR) in patients with a very small aortic annulus, and its clinical outcomes are reportedly satisfactory. Here, we analyzed the left ventricular (LV) performance after AVR with the 16-mm ATS mechanical valve, based on the concept of cardiac energetics analysis. Eleven patients who underwent AVR with the 16-mm ATS mechanical valve were enrolled in this study. All underwent echocardiographic examination at three time points: before AVR, approximately 1 month after AVR, and approximately 1 year after AVR. LV contractility (end-systolic elastance [Ees]), afterload (effective arterial elastance [Ea]), and efficiency (ventriculoarterial coupling [Ea/Ees] and the stroke work to pressure–volume area ratio [SW/PVA]) were noninvasively measured by echocardiographic data and blood pressure measurement. Ees transiently decreased after AVR and then recovered to the pre-AVR level at the one-year follow-up. Ea significantly decreased in a stepwise manner. Consequently, Ea/Ees and SW/PVA were also significantly improved at the one-year follow-up compared with those before AVR. The midterm LV performance after AVR with the 16-mm ATS mechanical valve was satisfactory. AVR with the 16-mm ATS mechanical valve is validated as an effective treatment for patients with a very small aortic annulus. The cardiac energetics variables, coupling with the conventional hemodynamic variables, can contribute to a better understanding of the patients’ clinical conditions, and those may serve as promising indices of the cardiac function.
UR - http://www.scopus.com/inward/record.url?scp=84929941592&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=84929941592&partnerID=8YFLogxK
U2 - 10.1007/s10047-014-0769-x
DO - 10.1007/s10047-014-0769-x
M3 - Article
C2 - 24859744
AN - SCOPUS:84929941592
SN - 1434-7229
VL - 17
SP - 250
EP - 257
JO - Journal of Artificial Organs
JF - Journal of Artificial Organs
IS - 3
ER -