T1 - Blood leakage determination using the chromaticity of a color sensor
AU - Shimazaki, Takunori
AU - Kawakubo, Yoshifumi
AU - Hara, Shinsuke
AU - Hitosugi, Takashi
AU - Yokoyama, Takeshi
AU - Miki, Yoichiro
N1 - Publisher Copyright:
© 2019, Japanese Society for Medical and Biological Engineering. All rights reserved.
PY - 2019
Y1 - 2019
N2 - Percutaneous extracorporeal circulation therapies such as apheresis and hemodialysis are commonly used in intensive care units, hemodialysis centers, and clinically settings. In these treatments, there is always a possibility of continuous bleeding from the puncture site. Since the blood flow in these therapies is high, a hemorrhagic shock may be caused by severe blood loss, and-in the worst case-this may even lead to the pa-tient’s death. Therefore, it is important to continuously monitor blood leakage during the treatment. Typical procedures include the electrode method and the blood absorbance method, but their function may be affected by leakage of colored chemicals used, or by sweat or light. In this study, we developed a blood leakage determination module based on the chromaticity of a color sensor. Since the method is specifically sensitive to the red color, it can detect blood leakage. We performed experiments to verify the effectiveness of the proposed method and compared this new procedure with the existing ones, and we confirmed that the proposed method correctly detected blood leakage. Moreover, we investigated the blood detection capability of our new procedure and found that it could be applied to detect hematocrit levels within the range of 2% to 64%. We developed a mul-ticolor sensor module and established a blood leakage detection method to meet the conditions that we had set as our goal. Our study confirmed that the proposed method did not cause malfunction due to leakage of chemical or presence of obstacle in the light path, while the traditional methods did. We also evaluated its performance and found that our method was able to detect blood leakage within the hematocrit range of 2% to 64%.
AB - Percutaneous extracorporeal circulation therapies such as apheresis and hemodialysis are commonly used in intensive care units, hemodialysis centers, and clinically settings. In these treatments, there is always a possibility of continuous bleeding from the puncture site. Since the blood flow in these therapies is high, a hemorrhagic shock may be caused by severe blood loss, and-in the worst case-this may even lead to the pa-tient’s death. Therefore, it is important to continuously monitor blood leakage during the treatment. Typical procedures include the electrode method and the blood absorbance method, but their function may be affected by leakage of colored chemicals used, or by sweat or light. In this study, we developed a blood leakage determination module based on the chromaticity of a color sensor. Since the method is specifically sensitive to the red color, it can detect blood leakage. We performed experiments to verify the effectiveness of the proposed method and compared this new procedure with the existing ones, and we confirmed that the proposed method correctly detected blood leakage. Moreover, we investigated the blood detection capability of our new procedure and found that it could be applied to detect hematocrit levels within the range of 2% to 64%. We developed a mul-ticolor sensor module and established a blood leakage detection method to meet the conditions that we had set as our goal. Our study confirmed that the proposed method did not cause malfunction due to leakage of chemical or presence of obstacle in the light path, while the traditional methods did. We also evaluated its performance and found that our method was able to detect blood leakage within the hematocrit range of 2% to 64%.
UR - http://www.scopus.com/inward/record.url?scp=85078682968&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85078682968&partnerID=8YFLogxK
U2 - 10.14326/abe.8.177
DO - 10.14326/abe.8.177
M3 - Article
AN - SCOPUS:85078682968
SN - 2187-5219
VL - 8
SP - 177
EP - 184
JO - Advanced Biomedical Engineering
JF - Advanced Biomedical Engineering
ER -