TY - JOUR
T1 - Antibiotic susceptibility of glutaraldehyde-tolerant Mycobacterium chelonae from bronchoscope washing machines
AU - Nomura, Kazuyo
AU - Ogawa, Midori
AU - Miyamoto, Hiroshi
AU - Muratani, Tetsuro
AU - Taniguchi, Hatsumi
N1 - Funding Information:
This study was supported by Grant-in-Aid for Scientific Research (C) 14570253 from the Ministry of Education, Culture, Sports, Science and Technology, Japan.
PY - 2004/6
Y1 - 2004/6
N2 - Background Contamination of bronchoalveolar lavage fluid is a major problem in the world. Although 2% glutaraldehyde (GA) is widely used as a disinfectant for bronchoscope cleaning, recently, GA-tolerant mycobacteria have been isolated, which makes this problem more complicated. Methods We studied the susceptibility to GA and antibiotics of mycobacteria isolated from bronchoscope washing machines in our hospital. We also studied the minimum inhibitory concentrations of GA and antibiotics with pump inhibitors. Results Twenty-nine mycobacteria were isolated, of which 26 were Mycobacterium chelonae. Among 18 isolates of M chelonae, excluding 8 isolates in which some results were not reproducible, 50% (9 of 18) were 2% GA-tolerant. One hundred percent (9 of 9) of the GA-tolerant isolates and 11% (1 of 9) of the GA-sensitive isolates were either resistant or intermediately resistant to 2 or 3 classes of antibiotics. Efflux pump inhibitors did not influence the susceptibility to GA and antibiotics. Conclusions It was suggested that there might be an association of GA tolerance with antibiotic resistance in M chelonae. There may a different mechanism(s) other than that involving efflux pumps with regard to GA tolerance and antibiotic resistance in M chelonae. When bronchoscopy-related mycobacterial infections are suspected, physicians and clinical microbiologists should exercise care in handling GA-tolerant mycobacteria, which may be resistant to multiple antibiotics.
AB - Background Contamination of bronchoalveolar lavage fluid is a major problem in the world. Although 2% glutaraldehyde (GA) is widely used as a disinfectant for bronchoscope cleaning, recently, GA-tolerant mycobacteria have been isolated, which makes this problem more complicated. Methods We studied the susceptibility to GA and antibiotics of mycobacteria isolated from bronchoscope washing machines in our hospital. We also studied the minimum inhibitory concentrations of GA and antibiotics with pump inhibitors. Results Twenty-nine mycobacteria were isolated, of which 26 were Mycobacterium chelonae. Among 18 isolates of M chelonae, excluding 8 isolates in which some results were not reproducible, 50% (9 of 18) were 2% GA-tolerant. One hundred percent (9 of 9) of the GA-tolerant isolates and 11% (1 of 9) of the GA-sensitive isolates were either resistant or intermediately resistant to 2 or 3 classes of antibiotics. Efflux pump inhibitors did not influence the susceptibility to GA and antibiotics. Conclusions It was suggested that there might be an association of GA tolerance with antibiotic resistance in M chelonae. There may a different mechanism(s) other than that involving efflux pumps with regard to GA tolerance and antibiotic resistance in M chelonae. When bronchoscopy-related mycobacterial infections are suspected, physicians and clinical microbiologists should exercise care in handling GA-tolerant mycobacteria, which may be resistant to multiple antibiotics.
UR - http://www.scopus.com/inward/record.url?scp=3042756785&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=3042756785&partnerID=8YFLogxK
U2 - 10.1016/j.ajic.2003.07.007
DO - 10.1016/j.ajic.2003.07.007
M3 - Article
C2 - 15175610
AN - SCOPUS:3042756785
SN - 0196-6553
VL - 32
SP - 185
EP - 188
JO - American Journal of Infection Control
JF - American Journal of Infection Control
IS - 4
ER -