T1 - Advantageous application of a surface coil to EPR irradiation in overhauser-enhanced MRI
AU - Matsumoto, Shingo
AU - Yamada, Kenichi
AU - Hirata, Hiroshi
AU - Yasukawa, Keiji
AU - Hyodo, Fuminori
AU - Ichikawa, Kazuhiro
AU - Utsumi, Hideo
PY - 2007/4
Y1 - 2007/4
N2 - The present study describes the advantageous application of a surface coil to electron paramagnetic resonance (EPR) irradiation in Overhauser-enhanced MRI (OMRI). OMRI is a double-resonance method for imaging free radicals based on the Overhauser effect. Proton NMR images are recorded without and with EPR irradiation of the free radical resonance, which results in a difference proton image that shows signal enhancement in spatial regions that contain the free radical. To obtain good signal enhancement in OMRI, very high RF power and a long EPR irradiation time are required. To improve sensitivity and shorten the image acquisition time, especially for localized (and topical) applications, we developed and tested a surface-coil-type EPR irradiation coil. Theoretical calculations and experimental data showed that EPR irradiation through the surface coil could ameliorate the localized Overhauser enhancement, which was related to the ratio of B1 surface coil/B1 volume coil in the region of interest (ROI), as expected. The increased sensitivity could also be converted into a shortened EPR irradiation time, resulting in fast data acquisition. For biomedical applications, the use of a surface coil (as opposed to a conventional volume coil) could decrease the total RF power deposition in the sample required to obtain the same Overhauser enhancement in the ROI.
AB - The present study describes the advantageous application of a surface coil to electron paramagnetic resonance (EPR) irradiation in Overhauser-enhanced MRI (OMRI). OMRI is a double-resonance method for imaging free radicals based on the Overhauser effect. Proton NMR images are recorded without and with EPR irradiation of the free radical resonance, which results in a difference proton image that shows signal enhancement in spatial regions that contain the free radical. To obtain good signal enhancement in OMRI, very high RF power and a long EPR irradiation time are required. To improve sensitivity and shorten the image acquisition time, especially for localized (and topical) applications, we developed and tested a surface-coil-type EPR irradiation coil. Theoretical calculations and experimental data showed that EPR irradiation through the surface coil could ameliorate the localized Overhauser enhancement, which was related to the ratio of B1 surface coil/B1 volume coil in the region of interest (ROI), as expected. The increased sensitivity could also be converted into a shortened EPR irradiation time, resulting in fast data acquisition. For biomedical applications, the use of a surface coil (as opposed to a conventional volume coil) could decrease the total RF power deposition in the sample required to obtain the same Overhauser enhancement in the ROI.
UR - http://www.scopus.com/inward/record.url?scp=34248400703&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=34248400703&partnerID=8YFLogxK
U2 - 10.1002/mrm.21198
DO - 10.1002/mrm.21198
M3 - Article
C2 - 17390363
AN - SCOPUS:34248400703
SN - 0740-3194
VL - 57
SP - 806
EP - 811
JO - Magnetic Resonance in Medicine
JF - Magnetic Resonance in Medicine
IS - 4
ER -