Abstract
In this paper, saturation magnetization measurement was successfully applied to evaluate the volume fraction of metastable retained austenite (γR) in low-carbon TRIP aided multi-phase steel sheet. The γR of this steel becomes unstable at the surface due to a lack of lattice constraint. The X-ray method, conventional method, proved to evaluate the volume fraction at the surface. On the other hand, saturation magnetization proved to be comparatively an accurate method due to the inherent bulkiness of the YR.
Original language | English |
---|---|
Pages (from-to) | 43-45 |
Number of pages | 3 |
Journal | R and D: Research and Development Kobe Steel Engineering Reports |
Volume | 52 |
Issue number | 3 |
Publication status | Published - 2002 |
Externally published | Yes |
All Science Journal Classification (ASJC) codes
- Metals and Alloys