TY - JOUR
T1 - A new HPLC-DAD method for the concurrent determination of hydroquinone, hydrocortisone acetate and tretinoin in different pharmaceuticals for melasma treatment
AU - Ibrahim, Fawzia
AU - Sharaf El-Din, Mohie K.
AU - El-Deen, Asmaa Kamal
AU - Shimizu, Kuniyoshi
N1 - Publisher Copyright:
© 2019 The Author(s). Published by Oxford University Press. All rights reserved.
PY - 2019/7/1
Y1 - 2019/7/1
N2 - A new simple and robust HPLC-DAD method was developed for the concurrent analysis of hydroquinone (HQ), hydrocortisone acetate (HCA) and tretinoin (TRN) triple combination for the first time using an Inertsil ODS 3-C18 column (150 mm × 4.6 mm, 5 μm particle size) column with 0.05 M phosphate buffer (pH 5.0) and acetonitrile at a ratio of (10:90, v/v) as a mobile phase, eluted by an isocratic elution mode at a flow rate of 1.0 mL/min and detected at 265 nm. Mefenamic acid was used as an internal standard (I.S.). The method produced linear responses in the concentration range of 10-200, 5-100 and 1-40 μg/mL, with detection limits of 2.01, 1.13 and 0.28 × 10-3 and quantitation limits of 6.11, 3.41 and 0.87 × 10-3 μg/mL for HQ, HCA and TRN, respectively, and a correlation coefficient higher than 0.9998. All validation requirements were satisfied by proving its linearity, precision, accuracy, robustness and specificity. The method was extended for application in triple combination cream, HQ/TRN co-formulated cream and HQ and TRN single ingredient cream with a recovery >97%.
AB - A new simple and robust HPLC-DAD method was developed for the concurrent analysis of hydroquinone (HQ), hydrocortisone acetate (HCA) and tretinoin (TRN) triple combination for the first time using an Inertsil ODS 3-C18 column (150 mm × 4.6 mm, 5 μm particle size) column with 0.05 M phosphate buffer (pH 5.0) and acetonitrile at a ratio of (10:90, v/v) as a mobile phase, eluted by an isocratic elution mode at a flow rate of 1.0 mL/min and detected at 265 nm. Mefenamic acid was used as an internal standard (I.S.). The method produced linear responses in the concentration range of 10-200, 5-100 and 1-40 μg/mL, with detection limits of 2.01, 1.13 and 0.28 × 10-3 and quantitation limits of 6.11, 3.41 and 0.87 × 10-3 μg/mL for HQ, HCA and TRN, respectively, and a correlation coefficient higher than 0.9998. All validation requirements were satisfied by proving its linearity, precision, accuracy, robustness and specificity. The method was extended for application in triple combination cream, HQ/TRN co-formulated cream and HQ and TRN single ingredient cream with a recovery >97%.
UR - http://www.scopus.com/inward/record.url?scp=85067013559&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85067013559&partnerID=8YFLogxK
U2 - 10.1093/chromsci/bmz020
DO - 10.1093/chromsci/bmz020
M3 - Article
C2 - 30941396
AN - SCOPUS:85067013559
SN - 0021-9665
VL - 57
SP - 495
EP - 501
JO - Journal of chromatographic science
JF - Journal of chromatographic science
IS - 6
ER -