TY - JOUR
T1 - A new and practical Se(IV) removal method using Fe3+ type cation exchange resin
AU - Kawamoto, Daisuke
AU - Yamanishi, Yui
AU - Ohashi, Hironori
AU - Yonezu, Kotaro
AU - Honma, Tetsuo
AU - Sugiyama, Takeharu
AU - Kobayashi, Yasuhiro
AU - Okaue, Yoshihiro
AU - Miyazaki, Akane
AU - Yokoyama, Takushi
N1 - Publisher Copyright:
© 2019 Elsevier B.V.
PY - 2019/10/15
Y1 - 2019/10/15
N2 - An effective method for removing selenium (Se) from water is required from the viewpoint of environmental preservation. To establish this method, a cation exchange resin that adsorbed ferric ions was applied as an adsorbent. In this study, the adsorption behavior of Se to the adsorbent was examined by both batch and column methods. The batch experiment confirmed that selenite ions (Se(IV)) are effectively adsorbed but selenate ions (Se(VI)) are hardly adsorbed. To elucidate the adsorption mechanism, the Fe in the adsorbent and the Fe in the adsorbent after the adsorption of Se(IV) were characterized by Fe K-edge X-ray absorption spectroscopy and 57Fe Mӧssbauer spectroscopy. The analytical result of Se K-edge EXAFS spectra for the Se(IV) adsorbed on the adsorbent suggests that Se(IV) are adsorbed specifically to the adsorbent through the formation of Fe-O-Se bonds. The breakthrough curve obtained by the column experiment showed that Se(IV) in 3 tons of synthetic solution containing 0.1 ppm Se can be efficiently removed using a column in which 12.8 g (10.4 cm3) of the adsorbent was packed.
AB - An effective method for removing selenium (Se) from water is required from the viewpoint of environmental preservation. To establish this method, a cation exchange resin that adsorbed ferric ions was applied as an adsorbent. In this study, the adsorption behavior of Se to the adsorbent was examined by both batch and column methods. The batch experiment confirmed that selenite ions (Se(IV)) are effectively adsorbed but selenate ions (Se(VI)) are hardly adsorbed. To elucidate the adsorption mechanism, the Fe in the adsorbent and the Fe in the adsorbent after the adsorption of Se(IV) were characterized by Fe K-edge X-ray absorption spectroscopy and 57Fe Mӧssbauer spectroscopy. The analytical result of Se K-edge EXAFS spectra for the Se(IV) adsorbed on the adsorbent suggests that Se(IV) are adsorbed specifically to the adsorbent through the formation of Fe-O-Se bonds. The breakthrough curve obtained by the column experiment showed that Se(IV) in 3 tons of synthetic solution containing 0.1 ppm Se can be efficiently removed using a column in which 12.8 g (10.4 cm3) of the adsorbent was packed.
UR - http://www.scopus.com/inward/record.url?scp=85066933579&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85066933579&partnerID=8YFLogxK
U2 - 10.1016/j.jhazmat.2019.04.076
DO - 10.1016/j.jhazmat.2019.04.076
M3 - Article
C2 - 31202056
AN - SCOPUS:85066933579
SN - 0304-3894
VL - 378
JO - Journal of Hazardous Materials
JF - Journal of Hazardous Materials
M1 - 120593
ER -