TY - JOUR
T1 - 4D ASL-based MR angiography for visualization of distal arteries and leptomeningeal collateral vessels in moyamoya disease
T2 - a comparison of techniques
AU - Togao, Osamu
AU - Hiwatashi, Akio
AU - Obara, Makoto
AU - Yamashita, Koji
AU - Momosaka, Daichi
AU - Nishimura, Ataru
AU - Arimura, Koichi
AU - Hata, Nobuhiro
AU - Yoshimoto, Koji
AU - Iihara, Koji
AU - Van Cauteren, Marc
AU - Honda, Hiroshi
N1 - Funding Information:
Funding This study has received funding by JSPS KAKENHI grant no. JP 17K10410.
Publisher Copyright:
© 2018, European Society of Radiology.
PY - 2018/11/1
Y1 - 2018/11/1
N2 - Objectives: To evaluate the performance of four-dimensional pseudo-continuous arterial spin labeling (4D-pCASL)-based angiography using CENTRA-keyhole and view sharing (4D-PACK) in the visualization of flow dynamics in distal cerebral arteries and leptomeningeal anastomosis (LMA) collaterals in moyamoya disease in comparison with contrast inherent inflow-enhanced multiphase angiography (CINEMA), with reference to digital subtraction angiography (DSA). Methods: Thirty-two cerebral hemispheres from 19 patients with moyamoya disease (mean age, 29.7 ± 19.6 years; five males, 14 females) underwent both 4D-MR angiography and DSA. Qualitative evaluations included the visualization of anterograde middle cerebral artery (MCA) flow and retrograde flow via LMA collaterals with reference to DSA. Quantitative evaluations included assessments of the contrast-to-noise ratio (CNR) on these vessels. The linear mixed-effect model was used to compare the 4D-PACK and CINEMA methods. Results: The vessel visualization scores were significantly higher with 4D-PACK than with CINEMA in the visualization of anterograde flow for both Observer 1 (CINEMA, 3.53 ± 1.39; 4D-PACK, 4.53 ± 0.80; p < 0.0001) and Observer 2 (CINEMA, 3.50±1.39; 4D-PACK, 4.31 ± 0.86; p = 0.0009). The scores were higher with 4D-PACK than with CINEMA in the visualization of retrograde flow for both Observer 1 (CINEMA, 3.44 ± 1.05; 4D-PACK, 4.47 ± 0.88; p < 0.0001) and Observer 2 (CINEMA, 3.19 ± 1.20; 4D-PACK, 4.38 ± 0.91; p < 0.0001). The maximum CNR in the anterograde flow was higher in 4D-PACK (40.1 ± 16.1, p = 0.0001) than in CINEMA (27.0 ± 16.6). The maximum CNR in the retrograde flow was higher in 4D-PACK (36.1 ± 10.0, p < 0.0001) than in CINEMA (15.4 ± 8.0). Conclusions: The 4D-PACK provided better visualization and higher CNRs in distal cerebral arteries and LMA collaterals compared with CINEMA in patients with this disease. Key Points: • The 4D-PACK enables good visualization of distal cerebral arteries in moyamoya disease. • The 4D-PACK enables direct visualization of leptomeningeal collateral vessels in moyamoya disease. • Vessel visualization by 4D-PACK can be useful in assessing cerebral hemodynamics.
AB - Objectives: To evaluate the performance of four-dimensional pseudo-continuous arterial spin labeling (4D-pCASL)-based angiography using CENTRA-keyhole and view sharing (4D-PACK) in the visualization of flow dynamics in distal cerebral arteries and leptomeningeal anastomosis (LMA) collaterals in moyamoya disease in comparison with contrast inherent inflow-enhanced multiphase angiography (CINEMA), with reference to digital subtraction angiography (DSA). Methods: Thirty-two cerebral hemispheres from 19 patients with moyamoya disease (mean age, 29.7 ± 19.6 years; five males, 14 females) underwent both 4D-MR angiography and DSA. Qualitative evaluations included the visualization of anterograde middle cerebral artery (MCA) flow and retrograde flow via LMA collaterals with reference to DSA. Quantitative evaluations included assessments of the contrast-to-noise ratio (CNR) on these vessels. The linear mixed-effect model was used to compare the 4D-PACK and CINEMA methods. Results: The vessel visualization scores were significantly higher with 4D-PACK than with CINEMA in the visualization of anterograde flow for both Observer 1 (CINEMA, 3.53 ± 1.39; 4D-PACK, 4.53 ± 0.80; p < 0.0001) and Observer 2 (CINEMA, 3.50±1.39; 4D-PACK, 4.31 ± 0.86; p = 0.0009). The scores were higher with 4D-PACK than with CINEMA in the visualization of retrograde flow for both Observer 1 (CINEMA, 3.44 ± 1.05; 4D-PACK, 4.47 ± 0.88; p < 0.0001) and Observer 2 (CINEMA, 3.19 ± 1.20; 4D-PACK, 4.38 ± 0.91; p < 0.0001). The maximum CNR in the anterograde flow was higher in 4D-PACK (40.1 ± 16.1, p = 0.0001) than in CINEMA (27.0 ± 16.6). The maximum CNR in the retrograde flow was higher in 4D-PACK (36.1 ± 10.0, p < 0.0001) than in CINEMA (15.4 ± 8.0). Conclusions: The 4D-PACK provided better visualization and higher CNRs in distal cerebral arteries and LMA collaterals compared with CINEMA in patients with this disease. Key Points: • The 4D-PACK enables good visualization of distal cerebral arteries in moyamoya disease. • The 4D-PACK enables direct visualization of leptomeningeal collateral vessels in moyamoya disease. • Vessel visualization by 4D-PACK can be useful in assessing cerebral hemodynamics.
UR - http://www.scopus.com/inward/record.url?scp=85046683408&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=85046683408&partnerID=8YFLogxK
U2 - 10.1007/s00330-018-5462-7
DO - 10.1007/s00330-018-5462-7
M3 - Article
C2 - 29737389
AN - SCOPUS:85046683408
SN - 0938-7994
VL - 28
SP - 4871
EP - 4881
JO - European Radiology
JF - European Radiology
IS - 11
ER -