トレーサー試験による大霧地区地熱貯留層の水理構造特性評価 

Translated title of the contribution: Evaluation of hydrological feature of reservoir in the Ogiri geothermal field by tracer test

髙山 純一, 田中 俊昭, 糸井 龍一

Research output: Contribution to journalArticlepeer-review

Abstract

<p>We analyzed tracer tests in the Ogiri geothermal field, which was conducted in 2008 and 2011, respectively. The test results were analyzed with the multi-flowpath model, then interpreted together with hydrological features of the field determined from geological settings and geophysical surveys. The results indicate the presence of two flow path for reinjected water flowing to the production zone in the Ginyu fault. A part of the reinjected water flows into the main production zone of the Ginyu fault directly through this fault from the west. The water also flows the Ogiri deep faults zone located to the south of the Ginyu fault, then flows into the Ginyu fault from the east which takes longer time to reach the production zone.</p>
Translated title of the contributionEvaluation of hydrological feature of reservoir in the Ogiri geothermal field by tracer test
Original languageJapanese
Pages (from-to)129-140
Number of pages12
JournalJournal of the Geothermal Research Society of Japan
Volume39
Issue number3
DOIs
Publication statusPublished - 2017

Fingerprint

Dive into the research topics of 'Evaluation of hydrological feature of reservoir in the Ogiri geothermal field by tracer test'. Together they form a unique fingerprint.

Cite this